CES 476 Specifications
Non-Linearity:+.5% BFSL
+1% BFSR
Output: 4-20 mA into 1000 W Max.
Full Scale Pressure Ranges
Split Range: +.0025” to +.125” H2O
Zero Based: 0-.005” to 0-.25” H2O
Full Scale Flow Ranges
Uni-directional:0-280 FPM to 0-2000 FPM
Bi-directional: +150 FPM to +1400
Overpressure: 1 PSI HI Side Max.
.5 PSI low side Max.
Line Pressure:10 PSI Max.
Media:Air or other inert gases
Operating Temperature:0 to 450C
Thermal Zero Shift:Autozero
Thermal Span Shift:+.08%/0F
Input Turndown: 0 to 100% Live Zero all models
Power:24 VDC(3 wire) @ 200 mA
115 VAC(W wire) @ 100mA
DISPLAY
Type: .5 LCD;3 1/2 digit 1999 count
Decimal Points: User selectable
SPECIFICATION SUBJECT TO CHANGE WITHOUT NOTICE
ORDERING INFORMATION
CES 467-1-2-3-4-5
1POWER
3W: +24 VDC @ 200mA(3 wire)
4W: 120 VAC @ 100mA(4 wire)
2. Input Range
Specify desired full scale reading.
Full Scale Pressure Ranges
Split Range: +.0025” to +.125” H2O
Zero Based: 0-.005” to 0-.25” H2O
Full Scale Flow Ranges
Uni-directional:0-280 FPM to 0-2000
FPMBi-directional: +150 FPM to +1400
3. RESPONSE CURVE
L: LINEAR
SR: SQUARE ROOT
ST:S TYPE PITOT CURVE
BS:BI-DIRECTIONAL S TYPE CURVE
4.OPTIONS
LCD4:4 1/2 DIGIT LCD
Display will be calibrated to match Full scale pressure unless specified otherwise.
PINOUT:
1. GND
2. OUTPUT
3. + 24 VDC
4. NC
5. NC
6. NC
7. AC NEUTRAL
8. AC HOT
APPLICATION NOTES:
DIMENSIONS:
 |